SKF MonoFlex gear pump unit
Technical Data
Reservoir capacity ................... 2, 3, and 6 liters DC motor
Rated voltage ...................... 24 V DC
Dry weight
Rated current ...................... 1,6 A
Unit with 2 liter plastic reservoir ........ 3.4 kg
Starting current ..................... 4 A
Unit with 3 liter plastic reservoir ........ 4.2 kg
Rated output ....................... 39 W
Unit with 3 liter metal reservoir ......... 5 kg
Duty type as defined by DIN EN 60034-1
(VDE 0530)
2)
.......................
S3, 20% (1.25 bis 25 min)
Unit with 6 liter plastic reservoir ........ 5.6 kg
Integrated fuse for motor
Cartridge fuse link (5×20 mm)
according to DIN EN 60127-2
(VDE 0820-2) standard sheet 3 .........
T2 A
4)
Delivery rate
1)
MKU, MKL ......................... 0.1; 0.2; 0.5 l/min
MKF .............................. 0.1; 0.2 l/min
Recommended fuse protection (line protection)
according to DIN EN 60898 ............
B 6A or C 4A
Max. operating pressure .............. 30 bar
Operating temperature ............... +10 to 40 °C
Protection class per DIN EN 60529
(VDE 0470-1) ......................
Fill level switch for oil (contact opens when level is too low)
IP 54 Switched voltage range ...............
10 to 36 V DC/10 to 25 V AC
Switching current (resistive load)
3)
...... ≤ 0.25 A
Pumped media Switching capacity (resistive load) ....... ≤ 3 W/VA
MKU, MKL ......................... Mineral oil or
synthetic oil Fill level switch for oil (contact closes when level is too low)
Operating viscosity .................. 20–1500 mm
2
/s Switched voltage range ...............
10 to 36 V DC/10 to 25 V AC
MKF ..............................
Fluid grease NLGI Grade 000
or 00
Switching current (resistive load)
3)
...... ≤ 0.25 A
Switching capacity (resistive load) ....... ≤ 3 W/VA
Compatible with plastics, NBR
elastomers, copper and
copper alloysn
Fill level switch for fluid grease (contact opens when level is too low)
Operating voltage range .............. 10 to 36 V DC
Output current (resistive load)
3)
......... ≤ 0.25 A
Power consumption without output load . .
< 10 mA (24 V), < 15 mA (36 V)
AC motor
Short circuit and polarity reversal protection .
Yes
Rated frequency ....................
50 Hz 60 Hz
Rated voltage ......................
115/230 V 115/230 V
Pressure switch (NO contact)
Rated current ...................... 1,06/0,53 A 1,36/0,68 A Rated pressure ..................... 20 bar
Rated output ....................... 60 W 75 W Switched voltage range ...............
10 to 36 V DC/10 to 25 V AC
Switching current (resistive load)
3)
...... ≤ 1 A
Duty type as defined by DIN EN 60034-1
VDE 0530-1)
2)
.....................
Switching capacity (resistive load) ....... ≤ 10 W/VA
S3, 20% (1.25 to 25 min)
With integrated temperature switch Additional input power on units with control unit
IG38-30 / IZ38-30 .................. 4 W
Recommended fuse protection (line protection)
according to DIN EN 60898 ............
IG54-20 / IGZ36-20 ................. 8 W
B 6A
1)
Based on an operating viscosity of 140 mm
2
/s (cSt) at a back pressure of p = 5 bar.
2)
Mode S3 (periodic intermitent operation) describes the ratio between the pump cycle and the subsequent down time. The following limit values result from a relative ON-time of 20% and a cycle time of
1,25 to 25 min:
Min. cycle time: 1.25 min×0.2 = 0.25 min. Pump cycle with subsequent down time of 1 min.
Max. cycle time: 25 min×0.2 = 5 min. Pump cycle with subsequent down time of 20 min.
3)
When switching inductive loads, take suitable measures to protect the contacts.
4)
Minimum short-circuit current of 6A must be ensured.