PUB LS/P2 12133 EN · 1-1203-EN
Gear pump unit, product series MKU
Configurator
Order code
M K U – 1 0 0 0 +
Product series MKx
U = oil lubricant
Delivery rate
1 = 0.1 l/min
• • • –
2 = 0.2 l/min – • • •
5 = 0.5 l/min – • • •
Voltage key
Voltage Frequency Control
924
3)
24 V DC – A, B, E
428 230 V AC
50/60 Hz A, B, C, D, E
429 115 V AC
3)
Only possible with delivery rates 0.1 und 0.2 l/min
Selected code number for lubricant reservoir
Selected code letter for control
Selected code letter for monitoring
Selected code number for pressure gauge
Selected code number for electrical connection
Monitoring
X A B C
D E
Fill level switch
Without fill level switch • • – – – –
NC contact
(detection of
wire breakage)
– – • • – –
NO contact
(no detection
of wire breakage)
– – – – • •
Pressure switch 20 bar
Without pressure
switch
• – • – • –
NO contact – • – • – •
Code number
for delivery
rate
Lubricant reservoir, control
Lubricant reservoir 1 2 3 4
2 liters,
plastic
3 liters,
plastic
3 liters,
metal
6 liters,
plastic
Control
A =
no control,
with terminal strip
• • • •
B =
no control,
with terminal strip
and pushbutton
• • • •
C =
IG38-30-I
1)
– • • •
D =
IZ38-30-I
1)
– • • •
E =
IGZ36-20-S6-I
1)2)
– • • •
1)
If control C, D, or E is selected, monitoring C must be selected.
2)
If control E is selected, electrical connection 1 must be selected.
For description of control units, see page 16 –17.
Electrical connection
Control
A,
B
A, B
C,
D
E
Monitoring X A B C D E C C
Electrical connection
0 = 2 cable fittings – • • • • • • –
1 =
1 cable fitting
;
1 rectangular
connector
– • • • • • • •
2 =
1
circular connector
M12×1;
1 rectan-
gular connecto
r
4)
– • • • • • – –
3 =
1 sealing plug;
1 cable fitting
• – – – – – – –
4 =
1 sealing plug;
1 rectangular
connector
• – – – – – – –
4)
Only for design without control.
Pressure gauge
0 = without pressure gauge
1 = with pressure gauge
Order example
MKU1-11AC10000+924
• Gear pump unit for oil
• Delivery rate 0.1 l/min
• 1st generation
• 2 liter plastic reservoir
• No control, with terminal strip
• NC fill level switch,
NO pressure switch
• With pressure gauge
• 2 cable fittings
• Voltage 24 V DC
7